Delta Network Module (DVP01LC-SL)
Brand: Delta
Product Model: DVP01LC-SL
Electrical Specifications
Load cell module Voltage output
Rated power supply voltage/ power consumption 24 VDC (-15 to +20%) / 3W
Voltage Boundary 18 to 31.2 VDC
Max. current consumption 125 mA
Input signal range ± 40 mVDC
Sensibility +5 VDC +/-10%
Internal resolution 24 bits
Communication port RS-232, RS-485
Applicable sensor type 4-wire or 6-wire strain gauge
Temperature coefficient span ≤ ± 50 ppm/K v. E
Temperature coefficient zero point ≤ ± 0.4 μV/K
Linearity error ≤ 0.02%
Response time 2, 10, 20, 40, 80 ms × channels
4 measuring ranges 0 to 1 mV/V, 0 to 2 mV/V, 0 to 4 mV/V, 0 to 6mV/V
Max. distance for connecting to load cell 100 M
Max. current output 5VDC * 300 mA
Permitted load cell resistance 40 to 4,010 Ω
Common mode rejection (CMRR @50/60 Hz) ≥100dB
Dynamic value filter Setting range: K1 to K5
Average value filter Setting range: K1 to K100
Isolation method 500 VAC between digital circuits and Ground
500 VAC between analog circuits and Ground
500 VAC between analog circuits and digital circuits
Series connection to DVP-PLC MPU Connectable to the left side of MPU, numbered from 100 to 107 according to the position of module from the closest to farthest to MPU.
Operation / storage temperature Operation: 0 to 55°C (temp.), 50 to 95% (humidity), pollution degree 2
Storage: -25 to 70°C (temp.), 5 to 95% (humidity)
Vibration / shock immunity International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/
IEC61131-2 & IEC 68-2-27 (TEST Ea)
*Complying with DIN1319-1, the tolerance of measured value should be <=0.05% under 200C + 10K temperature range.